Industrial Weighbridge Re-installation, Site Relocation & Civil Works
End-to-end engineered relocation of 12m to 24m weighbridges including structural anti-torsion dismantling, low-bed heavy haulage logistics, BNBC-grade civil foundation casting, and guaranteed BSTI legal metrology re-stamping anywhere across Bangladesh.
100%
Sensor Integrity Rate
< 2.0mm
Laser Level Max Tolerance
4000+
PSI Concrete Grade
Engineered Protocol
Systematic Scale Breakdown Isolation & Resolution
Transferring heavy scales without damage requires precision metrology at every step. We manage electrical backup, civil foundations, structural rigging, and legal verification under one single accountable contract.
01
Decommissioning & Tagging
Electrical decoupling and systematic tagging to preserve sensor calibrations and junction box topologies.
- Indicator memory dump & calibration profile archive.
- Theodolite level position indexing of analog & digital load cells.
- Shielded cable extraction with shock-proof crating.
02
Rigging & Heavy Haulage
Anti-torsion deck lifting protocols using multi-crane tandem systems and low-bed haulage across all districts.
- Calculated spreader-beam rigging to prevent beam flex
- Low-bed multi-axle trailers (up to 24m platform capability)
- Bangladesh Highway Division over-dimensional transit permits
03
Civil Works & Foundation
Precision civil engineering compliant with Bangladesh National Building Code (BNBC) and soil bearing ratings.
- Soil bearing capacity (SBC) geotechnical assessment
- C30/4000+ PSI concrete foundation & anchor embedment
- Integrated drainage sump pits and approach ramp slabs
04
Assembly & BSTI Stamping
Laser-assisted leveling, load cell recalibration, corner load matching, and formal BSTI legal inspection.
- Theodolite, Laser level alignment: tolerance < 2mm across whole span
- Standard Test Weight dead-load verification
- BSTI inspector verification, lead sealing & certificate issuance
Structural Accuracy
Zero-Tolerance Structural Calibration
A weighbridge is only as accurate as the concrete foundation it rests on. Deflection in civil base plates causes uneven load distribution and sensor failure. Nexpro guarantees strict adherence to civil tolerances.
Laser Base Plate Coplanarity
All bottom mounting plates align within ±1.5mm absolute tolerance.
Lightning & Surge Grounding
Dedicated copper grounding spike network with earthing resistance < 1Ω
Pitless Foundation Blueprint (Cross-Section)
Reinforcement: 72.5 Grade Deformed Bar
Soil Stabilization: Geo-textile + Sand Piling Available
Engineering Consultation
Request Relocation Feasibility Survey
Submit scale specifications and transit routes. Our Chief Structural Engineer inspects both origin and destination sites to produce certified feasibility reports and route permits.
Direct Technical Hotline
+880 1712-345083